Sonic Soot Blower Features
|
NO. |
Design parameters |
Unit |
Figure |
|
1 |
Manufacturers |
LEMOND |
|
|
2 |
Product model |
LMD-HORN |
|
|
3 |
Sound supply pressure |
MPa |
0.6 |
|
4 |
Effective scope of work (forward) |
M |
12-16 |
|
5 |
Effective scope of work (both sides) |
M |
4-6 |
|
6 |
Voice frequency |
Hz |
75 |
|
7 |
Acoustic pressure |
dB |
147 |
|
8 |
Maximum operating temperature |
℃ |
900 |
|
9 |
Solenoid valve voltage |
220VAC 3/4” |
|
|
10 |
Air inlet pipe diameter |
Mm |
2/3” |
|
11 |
Weight |
Kg |
80 |
|
12 |
Acoustic horn material |
SS304 |
|
|
13 |
Sound gas consumption |
L/s |
10-15 |
|
14 |
Interval of each sweep |
S |
590s |
|
15 |
Maintenance time per sweep |
s/time |
10 |
|
16 |
Compressed air consumption (per unit) |
Nm3/min |
1.14—2.28 |
1. Simple structure, Sonic soot blower body no need electricity, there is no mechanical movement and rotation mechanism and no vulnerable parts, so it’s easy for operation and maintenance.
2. Small size, lightweight, no retractable mechanism, will not lead to jam and stopped.
3. The material is resistant to high temperature, abrasion, corrosion, and aging, with a long service period.
4. It is safe and reliable, will not wear or blow the tube bundle, and will not cause tube explosion, meeting the requirements of personal safety and industrial labor protection regulations.
5. High acoustic efficiency, high power, wide frequency band, and remarkable ash removal effect.
6. It is applicable to various boiler types and any part of the boiler, including a furnace water wall, superheater, reheater, economizer, air preheater, electric precipitator, etc.
7. The installation range is wide. In addition to opening holes on the furnace wall, the original soot blower holes, coke holes, fire observation holes, and other positions can be used for installation.
8. Convenient installation, no need to set up a soot blower platform, small space occupied inside and outside the furnace wall, and no impact on boiler maintenance.
9. The control system is divided into automatic and manual functions, which can form a unit by itself or can be connected to the DCS system to realize fully automatic operation.
|
|
|
Sonic Soot Blower Application
Sonic soot blower could be used in various fields, it is applicable to various boiler types and any part of the boiler, including a furnace water wall, superheater, reheater, economizer, air preheater, electric precipitator, etc.
And for soot blower Desulfurization and denitration retrofit project, usually need to install a new sonic soot blower or Rake type soot blower for SCR catalyst, to meet the environmental requirements.
|
|
|
Sonic Sootblower Installation Method
1、 Keep the sealing plate in place according to the thickness of the furnace wall.
2、 Extend the acoustic soot blower to the soot blower hole, weld the sealing plate to the steel plate of the furnace wall, and weld with the straight pipe of the soot blower.
3、 To connect the air source piping, first add a flat cover and a blanking plate at the flange of the acoustic soot blower, loosen the flange gap and purge the pipeline. The soot-blowing air source is a 6-8kg high-pressure air source. The blanking plate can be removed and the pipeline can be connected only after it is confirmed that all the pipelines are purged clean (generally, it needs to be purged for more than 3 hours).
|
|
|
|
|
|
Sonic Sootblower Packaging
![]() |
|
|
|
|
|
Hot Tags: SCR sonic soot blower, China, manufacturers, suppliers, customized, wholesale, buy, low price, SCR Acoustic Soot Blower, Maintanence free Sonic Soot Blower, Sonic Soot Blower In Boiler, Compress Air Acoustic Soot Blower, SCR Sonic Soot Blower, Convenient Installation Soot Blower